keywords:

×

keyword:

L
L
UltraScan I

UltraScan I 20 mm

The product is mainly used for the processing of non-metallic and partial metallic materials, and it has been widely used in the laser processing fields such as food packaging, beverage packaging, medicine packaging, building ceramics, buttons, craft gifts, electronic components, mobile phone shells, laptop and tablet shells, wire stripping, film cutting, PCB barcodes, shell nameplate, etc.


Features

01

Low noise, high linearity and low drift

02

Applicable to a variety of F-theta lenses

03

Modular design, easy integration and maintenance

04

Standard protocol: 16bit XY2-100, 20bit ST2-100

Parameters

UltraScan I20 mm
Input Beam Aperture (mm)20
Beam Displacement (mm)25.25
Tracking Error (ms)0.45
Repeatability (µrad)<2
Offset Drift (µrad/K)<15
Gain Drift (ppm/K)<80
Long-Term Drift over 8h (mrad)<0.15
1% of Full Travel (ms)0.8
10% of Full Travel (ms)2.5
Positioning Speed (m/s)①5
Scan Angle (°)②± 25
Gain Error (mrad)<5
Offset Error (mrad)<5
Nonlinearity (%)<0.4
Power Requirements±15VDC, ≥3A
Communication Protocol16bit: XY2-100;20bit: ST2-100③
Operation Temperature (℃)25±10
Weight (kg)5
*All specifications are typical data and subject to change without notice due to product improvements.
①Test using F-theta lens with focal length F=160mm
②All angles above are optical angles